Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel | |
| 8 ohms 20Hz-20KHz 0.03% THD | 250W | |
| 4 ohms 20Hz-20KHz 0.05% THD | 400W | |
| 8 ohms EIA 1KHz 1% THD | 275W | |
| 4 ohms EIA 1KHz 1% THD | 440W | |
| 2 ohms EIA 1KHz 1% THD | 560W | |
| Bridge Mono Mode | Continuous Average Output Power | |
| 8 ohms 20Hz-20KHz 0.1% THD | 800W | |
| 4 ohms 1KHz 1% THD | 1120W | Subwoofer output | NA |
| Input sensitivity | 1.23 Vrms | |
| Noise (unweighted 20Hz-20KHz below rated output) | 106dB | |
| Distort ion(SMPTE-IM) | <0.01% | |
| Damping Factor | >200 @ 8 ohms | |
| Output Circuitry | Class H Amplifier | |
| Filtering | High pass filter (30Hz, 50Hz) | |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced | |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) | |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts | |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights | |
| Controls | ||
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) | |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) | |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, | |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz | |
| Dimensions (WxHxD) | 482.6 x 88 x 415mm (19" x 3.46" x 16.3") | |
| Weight | 17.5kg (38.5 lbs) | Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 400W |
| 4 ohms 20Hz-20KHz 0.05% THD | 600W |
| 8 ohms EIA 1KHz 1% THD | 450W |
| 4 ohms EIA 1KHz 1% THD | 660W |
| 2 ohms EIA 1KHz 1% THD | 960W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 1200W |
| 4 ohms 1KHz 1% THD | 1920W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >200 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 21.8kg (48 lbs) |
Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 400W |
| 4 ohms 20Hz-20KHz 0.05% THD | 600W |
| 8 ohms EIA 1KHz 1% THD | 450W |
| 4 ohms EIA 1KHz 1% THD | 660W |
| 2 ohms EIA 1KHz 1% THD | 960W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 1200W |
| 4 ohms 1KHz 1% THD | 1920W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >200 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 21.8kg (48 lbs) | Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 600W |
| 4 ohms 20Hz-20KHz 0.05% THD | 1000W |
| 8 ohms EIA 1KHz 1% THD | 650W |
| 4 ohms EIA 1KHz 1% THD | 1100W |
| 2 ohms EIA 1KHz 1% THD | 1400W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 2000W |
| 4 ohms 1KHz 1% THD | 2800W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >500 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 24.2kg (53.3lbs) |
Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 600W |
| 4 ohms 20Hz-20KHz 0.05% THD | 1000W |
| 8 ohms EIA 1KHz 1% THD | 650W |
| 4 ohms EIA 1KHz 1% THD | 1100W |
| 2 ohms EIA 1KHz 1% THD | 1400W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 2000W |
| 4 ohms 1KHz 1% THD | 2800W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >500 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 24.2kg (53.3lbs) | Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 1050W |
| 4 ohms 20Hz-20KHz 0.05% THD | 1600W |
| 8 ohms EIA 1KHz 1% THD | 1100W |
| 4 ohms EIA 1KHz 1% THD | 1800W |
| 2 ohms EIA 1KHz 1% THD | 2500W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 3200W |
| 4 ohms 1KHz 1% THD | 5000W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >500 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 28.2kg (62.1bs) |
Product Description:Phonic XP Series power amplifiers deliver from 280 to 5000 Watts of power in two to three rack spaces. Built around robust and advanced toroidal transformers, they deliver clean power on demand. The advanced protection circuitry guards against short circuit and open circuit, and also protects against ultrasonic and RF interference. A high current power supply increases reliability and performance. Other features include center-detented gain controls, input peak limiter, selectable high pass filter, and fast recovery to ensure low distortion. The variable speed fans effectively cool the amp and protect against overheating. Input is through XLR or 1/4" connectors, while you can use Speakon-type or binding post connectors for output. The XP 2100, 3100 and 5100 power amps have sub woofer outputs with a selectable low pass filter at 60, 90 or 120 Hz. Phonic XP Power Amplifiers are specially designed for professionals who value high power, audio clarity, reliability and lasting performance. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8 ohms 20Hz-20KHz 0.03% THD | 1050W |
| 4 ohms 20Hz-20KHz 0.05% THD | 1600W |
| 8 ohms EIA 1KHz 1% THD | 1100W |
| 4 ohms EIA 1KHz 1% THD | 1800W |
| 2 ohms EIA 1KHz 1% THD | 2500W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8 ohms 20Hz-20KHz 0.1% THD | 3200W |
| 4 ohms 1KHz 1% THD | 5000W |
| Subwoofer output | Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz (XP 2100, XP 3100, 5100 only) |
| Input sensitivity | 1.23 Vrms |
| Noise (unweighted 20Hz-20KHz below rated output) | 107dB |
| Distortion(SMPTE-IM) | <0.02% |
| Damping Factor | >500 @ 8 ohms |
| Output Circuitry | Class H Amplifier |
| Filtering | High pass filter (30Hz, 50Hz) |
| Frequency Response | 20Hz-20KHz, 0/-1dB -3dB points: 5Hz-100KHz |
| Input Impedance | 20 K ohms balanced, 10 K ohms unbalanced |
| Cooling | Dual continous variable-speed fans, front-to-rear air flow (one fan on 5000/5100, rear to front air flow) |
| Connectors (each channel) | Input: XLR & 1/4" TRS jacks; barrier strip (5000/5100) Output: SpeakonŽ-type and binding posts |
| Indicators | Power: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight icon CLIP/LIM: Red LED; PROTECT: Yellow Green LED for -10dB, -20dB and -40dB Signal Lights |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents Selectable low frequency crossover at 60Hz, 90Hz and 120Hz (XP 2100, XP and 3100 only) |
| Rear panel | Slide switches: Limiter On/Off; Operation modes: Parallel, Stereo, Bridge Mono Grounding / Floating and Selectable low cut filter at 30Hz and 50Hz (low pass filters on 5000/5100 only) |
| Amplifier Protection | Short circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and transformer over-heat protection, |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 133 x 415mm (19" x 5.2" x 16.3") |
| Weight | 28.2kg (62.1bs) |
Product Description:Phonic´s MAX 250 Power Amplifier provides 80 Watts of power at 4 ohms (stereo) in a single rack space - ideal for smaller venues and for monitoring purposes. The MAX 250 features ground switches, and the option to choose between stereo or parallel operating modes. Input to the MAX 250 amp is achieved via an XLR and a phone jack, and output can be achieved through binding posts, making this amplifier ideal for real world application. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8? EIA 1kHz 0.1%THD | 60W |
| 4? EIA 1kHz 0.1%THD | 80W |
| Output Circuitry | Class H |
| Input sensitivity @ 8? | 1.23V (+4dBu) |
| Distortion (SMPTE-IM) | <0.01% |
| Noise (unweighted 20 Hz - 20 kHz below rated output) | 103 dB |
| Damping Factor | >300 @ 8? |
| Frequency Response | 20 Hz-20KHz, +0/-1dB; -3dB points: 5Hz-50KHz |
| Input Impedance | 20 K ? balanced, 10 K ? unbalanced |
| Cooling | Convection |
| Connectors (each channel) | Input: XLR & 1/4" TRS; Output: 5-way binding posts |
| Indicators | Power: Blue LED; Signal: Green LED; Clip: Red LED |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents |
| Rear panel | Slide switches: Operation mode: Parallel, Stereo; Grounding / Floating |
| Protection Circuitry | Short circuit, thermal, subsonic, RF protection, Output DC offset, Power on/off muting |
| Gain | 41x (30dB) |
| Power Comsuption | 80W |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
Product Description:Phonic´s MAX 500 Power Amplifier provides 120 Watts of power at 4 ohms (stereo) in a single rack space - ideal for medium-size venues and for monitoring purposes. MAX 500 features ground switches, and the option to choose between stereo or parallel operating modes. Input to the MAX 500 amp is achieved via XLR or phone jack, and output is achieved through binding posts, making the MAX series amplifiers ideal for real world application. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8? EIA 1kHz 0.1%THD | 90W |
| 4? EIA 1kHz 0.1%THD | 120W |
| Output Circuitry | Class H |
| Input sensitivity @ 8? | 1.23V (+4dBu) |
| Distortion (SMPTE-IM) | <0.01% |
| Noise (unweighted 20 Hz - 20 kHz below rated output) | 103 dB |
| Damping Factor | >300 @ 8? |
| Frequency Response | 20 Hz-20KHz, +0/-1dB; -3dB points: 5Hz-50KHz |
| Input Impedance | 20 K ? balanced, 10 K ? unbalanced |
| Cooling | Convection |
| Connectors (each channel) | Input: XLR & 1/4" TRS; Output: 5-way binding posts |
| Indicators | Power: Blue LED; Signal: Green LED; Clip: Red LED |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents |
| Rear panel | Slide switches: Operation mode: Parallel, Stereo; Grounding / Floating |
| Protection Circuitry | Short circuit, thermal, subsonic, RF protection, Output DC offset, Power on/off muting |
| Gain | 41x (30dB) |
| Power Comsuption | 210W |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482 x 44 x 340 mm (19" x 1.73" x 7.65") |
| Weight | 7.85 kg (17.3 lbs) | Product Description:Phonic´s MAX 860 Power Amplifier provides 600 Watts of power at 8 ohms (bridge mono) or 300 Watts at 4 ohms (stereo) - ideal for clubs, churches, auditoriums and more. Input to the MAX amps is achieved via XLR or phone jack, and output is achieved through either Speakon-type connectors or binding posts. MAX 860 features ground switches, user defeatable clip limiters, selectable high pass filters, and the option to choose between stereo, parallel and bridge operating modes, making the MAX series amplifiers ideal for real world application. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8Ω EIA 1kHz 0.1%THD | 200W |
| 4Ω EIA 1kHz 0.1%THD | 300W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8Ω EIA 1kHz 0.1%THD | 600W |
| Output Circuitry | Class H |
| Input sensitivity @ 8Ω | 1.23V (+4dBu) |
| Distortion(SMPTE-IM) | <0.01% |
| Noise (unweighted 20Hz-20KHz below rated output) | 100dB |
| Damping Factor | >300@8Ω |
| Frequency Response | 20 Hz-20KHz, +0/-1dB; -3dB points: 5Hz-50KHz |
| Input Impedance | 20 K Ω balanced, 10 K Ω unbalanced |
| Cooling | Continous variable-speed fan, front-to-rear air flow |
| Connectors (each channel) | Input: XLR & 1/4" TRS; Output: Speakon and binding posts |
| Indicators | Power: Blue LED; SIGNAL: Green LED; PEAK: Red LED, |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents |
| Rear panel | Slide switches: Limiter On/Off; Operation mode: Parallel, Stereo, Bridge Mono; Grounding / Floating; Selectable low cut filter at 30Hz and 50Hz |
| Protection Circuitry | Short circuit, thermal, subsonic, RF protection, Output DC offset, Power on/off muting |
| Power Comsuption | 600W |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/ 60Hz |
| Dimensions (WxHxD) | 482.6 x 88 x 415 mm (19" x 3.46" x 15.9") |
| Weight | 13.2 kg (29.1 lbs) |
Product Description:Phonic´s MAX 1500 Power Amplifier provides 900 Watts of power at 8 ohms (bridge mono) or 450 Watts at 4 ohms (stereo) - ideal for clubs, churches, auditoriums and more. Input to the MAX 1500 amp is achieved via XLR or phone jack, and output is achieved either through Speakon-type connectors or traditional binding posts. The MAX 1500 features ground switches, user defeatable clip limiters, selectable high pass filters, and the option to choose between stereo, parallel and bridge operating modes, making this amplifier ideal for real world application. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8Ω EIA 1kHz 0.1%THD | 280W |
| 4Ω EIA 1kHz 0.1%THD | 450W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8Ω EIA 1kHz 0.1%THD | 900W |
| Output Circuitry | Class H |
| Input sensitivity @ 8Ω | 1.23V (+4dBu) |
| Distortion(SMPTE-IM) | <0.01% |
| Noise (unweighted 20Hz-20KHz below rated output) | 100dB |
| Damping Factor | >300@8Ω |
| Frequency Response | 20 Hz-20KHz, +0/-1dB; -3dB points: 5Hz-50KHz |
| Input Impedance | 20 K Ω balanced, 10 K Ω unbalanced |
| Cooling | Continous variable-speed fan, front-to-rear air flow |
| Connectors (each channel) | Input: XLR & 1/4" TRS; Output: Speakon and binding posts |
| Indicators | Power: Blue LED; SIGNAL: Green LED; PEAK: Red LED, |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents |
| Rear panel | Slide switches: Limiter On/Off; Operation mode: Parallel, Stereo, Bridge Mono; Grounding / Floating; Selectable low cut filter at 30Hz and 50Hz |
| Protection Circuitry | Short circuit, thermal, subsonic, RF protection, Output DC offset, Power on/off muting |
| Power Comsuption | 900W |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60Hz |
| Dimensions (WxHxD) | 482.6 x 88 x 415 mm (19" x 3.46" x 15.9") |
| Weight | 14.6 kg (32.2 lbs) | Product Description:Phonic´s MAX 2500 Power Amplifier provides 1500 Watts of power at 8 ohms (bridge mono) or 750 Watts at 4 ohms (stereo)- ideal for medium to large-size clubs, churches, auditoriums and more. Input to the MAX 2500 amp is achieved via combo connectors that accept both XLR and 1/4" jacks, and output is achieved through either Speakon-type connectors or binding posts. The MAX 2500 features ground switches, user defeatable clip limiters, selectable high pass filters, and the option to choose between stereo, parallel and bridge operating modes, making this amplifier ideal for real world application. |
| Stereo Mode (driving both channels) | Continuous Average Output Power Per Channel |
| 8Ω EIA 1kHz 0.1%THD | 500W |
| 4Ω EIA 1kHz 0.1%THD | 750W |
| Bridge Mono Mode | Continuous Average Output Power |
| 8Ω EIA 1kHz 0.1%THD | 1500W |
| Output Circuitry | Class H |
| Input sensitivity @ 8Ω | 1.23V (+4dBu) |
| Distortion(SMPTE-IM) | <0.02% |
| Noise (unweighted 20Hz-20KHz below rated output) | 100dB |
| Damping Factor | >300@8Ω |
| Frequency Response | 20 Hz-20KHz, +0/-1dB; -3dB points: 5Hz-50KHz |
| Input Impedance | 20 K Ω balanced, 10 K Ω unbalanced |
| Cooling | Continous variable-speed fan, front-to-rear air flow |
| Connectors (each channel) | Input: XLR & 1/4" TRS; Output: Speakon and binding posts |
| Indicators | Power: Blue LED; SIGNAL: Green LED; PEAK: Red LED, |
| Controls | |
| Front panel | CH1 & CH2 GAIN knobs with 41 detents |
| Rear panel | Slide switches: Limiter On/Off; Operation mode: Parallel, Stereo, Bridge Mono; Grounding / Floating; Selectable low cut filter at 30Hz and 50Hz |
| Protection Circuitry | Short circuit, thermal, subsonic, RF protection, Output DC offset, Power on/off muting |
| Power Comsuption | 1400W |
| Power Requirement (depends on region) | 100-120VAC, 220-240VAC, 50/60HZ |
| Dimensions (WxHxD) | 482.6 x 88 x 415 mm (19" x 3.46" x 15.9") |
| Weight | 16.5 kg (36.4 lbs) |
Product Description:ICON Series power amplifiers are designed with the needs of sound contractors in mind. The binding post outputs allow for connection to standard low impedance speakers. Barrier strip outputs enable 25V, 70V and 100V Line operation. Each amplifier channel has a separate toroidal secondary transformer that provides full electrical isolation and ensures maximum audio separation. Features like power up muting, full short-circuit temperature, DC offset protection and a built-in 45 Hz subsonic filter, combine to make the Icon Series an attractive, cost effective solution for any audio installation. |
| Direct Power Out | |
| Max.average power at 45Hz-20kHz With 0.1% THD | |
| 8 ohm | 120W×2 |
| 4 ohm | 200W×2 |
| 2 ohm,1kHz,1%THD | 300W×2 |
| Bridged mono 8 ohm,1kHz,1%THD | 420W |
| Bridged mono 4 ohm,1kHz,1%THD | 540W |
| Isolated Constant Voitage Out | |
| 200V or 140V Bridege | 300W |
| 100V or 70V | 150W×2 |
| 25V | 120W |
| Frequency Response | |
| Direct Outputs (+0/-2dB) | 50Hz-50kHz |
| Isolated Outputs (+0/-2dB) | 50Hz-16kHz |
| Total Harmonic Distortion | <0.05 |
| Sensitivity (fro full output) | 1.02V |
| Voitage Gain | 28dB |
| Input Impedance | |
| Balanced/Unbalanced | 20k/10k ohm |
| Damping Factor | >200(direct output) |
| S/N Ratio | Less than 100dB below rated output (20Hz-20kHz) |
| Protection Circuits | Output offset voitage protection Heat sink overheat protection Transformer overheat protection Load shorting protection Power on/off protection |
| Controls | |
| Front Panel/ | Power Switch/ |
| Rear Panel | Ch1 & Ch2 gain controls (41 click); Parallel/Stereo/ Bridge switch |
| Connectors | |
| Input/ | XLR jack ×2,Barrier strip ×1/ |
| Output | Covered Barrier strip x2;heavy-duty binding post |
| Cooling | One dual speed fan |
| Indicators | Clip:Red Signal:Green Protect:Yellow Power: Red |
| Dimensions(H×W×D) | 132x480x428mm |
| Net Weight | 24.3KG |
| Shipping Weight | 26.0KG | Product Description:ICON Series power amplifiers are designed with the needs of sound contractors in mind. The binding post outputs allow for connection to standard low impedance speakers. Barrier strip outputs enable 25V, 70V and 100V Line operation. Each amplifier channel has a separate toroidal secondary transformer that provides full electrical isolation and ensures maximum audio separation. Features like power up muting, full short-circuit temperature, DC offset protection and a built-in 45 Hz subsonic filter, combine to make the Icon Series an attractive, cost effective solution for any audio installation. |
| Direct Power Out | |
| Max.average power at 45Hz-20kHz With 0.1% THD | |
| 8 ohm | 240W×2 |
| 4 ohm | 400W×2 |
| 2 ohm,1kHz,1%THD | 550W×2 |
| Bridged mono 8 ohm,1kHz,1%THD | 850W |
| Bridged mono 4 ohm,1kHz,1%THD | 1100W |
| Isolated Constant Voitage Out | |
| 200V or 140V Bridege | 700W |
| 100V or 70V | 350W×2 |
| 25V | 280W×2 |
| Frequency Response | |
| Direct Outputs (+0/-2dB) | 50Hz-50kHz |
| Isolated Outputs (+0/-2dB) | 50Hz-16kHz |
| Total Harmonic Distortion | <0.05 |
| Sensitivity (fro full output) | 1.02V |
| Voitage Gain | 32dB |
| Input Impedance | |
| Balanced/Unbalanced | 20k/10k ohm |
| Damping Factor | >200(direct output) |
| S/N Ratio | Less than 100dB below rated output (20Hz-20kHz) |
| Protection Circuits | Output offset voitage protection Heat sink overheat protection Transformer overheat protection Load shorting protection Power on/off protection |
| Controls | |
| Front Panel/ | Power Switch/ |
| Rear Panel | Ch1 & Ch2 gain controls (41 click); Parallel/Stereo/ Bridge switch |
| Connectors | |
| Input/ | XLR jack ×2, Barrier strip ×1/ |
| Output | Covered Barrier strip x2;heavy-duty binding post |
| Cooling | One dual speed fan |
| Indicators | Limit:Red Signal:Green Protect:Yellow Power: Red |
| Dimensions(H×W×D) | 132x480x428mm |
| Net Weight | 24.3KG |
| Shipping Weight | 26.KG |